beautypg.com

Network requirements, Requirements analysis, Configuration procedure – H3C Technologies H3C S5830V2 Series Switches User Manual

Page 47

background image

36

Fc1/0/4

VSAN 20:

Access Ports:

Fc1/0/2

Trunk Ports:

Fc1/0/4

VSAN configuration examples by using VFC interfaces

Network requirements

As shown in

Figure 20

, configure the SAN to meet the following requirements:

Server A can read and write only the data of Disk A and Disk B.

Server B can read and write only the data of Disk C.

Figure 20 Network diagram

Requirements analysis

To meet the network requirements, perform the following tasks:

Divide the SAN into two VSANs, VSAN 10 and VSAN 20. Each VSAN contains a server and disk
devices that can exchange data.

Configure the two interfaces connecting Switch A to servers to operate in F mode, and assign the

two interfaces to VSAN 10 and VSAN 20, respectively.

Configure the three interfaces connecting Switch B to disk devices to operate in F mode, and assign
the interfaces as trunk ports to VSAN 10 or VSAN 20.

Configure the interfaces connecting Switch A and Switch B to operate in E mode, and assign the
interfaces to VSANs 10 and 20 as trunk port, so that the link between the two FCF switches can

send and receive the frames of the two VSANs at the same time.

Configuration procedure

This section describes only the VSAN configurations.

1.

Configure Switch A: