Configuring FC tracert

Overview

In an FC SAN, use the fctracert command to obtain bidirectional routing information between source

and destination, and check the network connectivity.
You can use this feature to identify failed nodes and test network connectivity.
FC tracert includes two processes:

Uplink process—In this process, beginning from the source, each switch along the path to the
destination sends the Switch Trace Route (STR) packet to its next hop until the STR packet reaches the

destination switch. (If the destination of FC tracert is a node, the destination switch refers to the FC

switch directly connected to the node.) Each switch adds its uplink path information (including its
WWN and domain ID) to the STR packet. After the STR packet reaches the destination switch, the

downlink process starts.

Downlink process—In this process, beginning from the destination switch, each switch along the
path to the source switch sends the STR packet to its next hop until the STR packet reaches the source

switch. Each switch adds its downlink path information (with the same content as the uplink path
information) to the STR packet. When the source switch receives the STR packet, the FC tracert

process ends. The source outputs information (in the STR packet) about all uplink and downlink

switches along the path.

If an FC switch fails to forward the STR packet, the switch sets an error reason in the packet and sends the
packet (containing information about switches the packet has passed through) directly to the source

switch.

Figure 41

shows the FC tracert process.

Figure 41 FC tracert flowchart

The following describes the process of an FC tracert operation from Switch A to Switch C.

Source switch

Switch A

Intermediate switch

Switch B

Destination switch

Switch C

STR Request

STR ACC

STR Request

STR ACC

STR Request

STR ACC

STR Request

STR ACC