Configuring zone distribution and merge types – H3C Technologies H3C S5830V2 Series Switches User Manual

Page 107

background image

96

Configuring zone distribution and merge types

Complete distribution (or merge) distributes (or merges) both the active zone set and zone database.
Incomplete distribution (or merge) distributes (or merges) only the active zone set.
The configured distribution type applies to distribution operations triggered by the zoneset activate

command instead of the zoneset distribute command.
The configured merge type applies to all merge operations.
To configure zone distribution and merge types:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter VSAN view.

vsan vsan-id

N/A

3.

Configure zone
distribution and merge

types as complete
distribution and complete

merge.

zoneset distribute full

The default setting is incomplete
distribution and incomplete merge.

Activating a zone set and distributing it to the entire

fabric

You can activate a zone set as the active zone set on a switch, distribute the active zone set to the entire

fabric, and implement access control through the active zone set. The modifications to the active zone set

do not take effect until reactivation.
The zone set to be activated must have been created and must contain at least one N_Port member. Only
one active zone set can exist in a VSAN.
When distributing the active zone set to the entire fabric, the device determines whether to carry zone

database information according to the distribution type specified by the zoneset distribute full

command.
To activate a zone set and distribute it to the entire fabric:

Step Command

1.

Enter system view.

system-view

2.

Enter VSAN view.

vsan vsan-id

3.

Activate the specified zone set as the active zone
set and distribute it to the entire fabric.

zoneset activate name zoneset-name

NOTE:

Active zone set information will not contain the alias names of zone members. If a zone in the active zone
set has members with a zone alias, the non-overlapping N_Port members in the zone alias are directly
added to the zone. You can view the zone member change by using the display zoneset active command.