beautypg.com

H3C Technologies H3C S5830V2 Series Switches User Manual

Page 160

background image

149

[SwitchC-Ten-GigabitEthernet1/0/2] port trunk permit vlan 10

[SwitchC-Ten-GigabitEthernet1/0/2] quit

# Enable FCoE for VLAN 10, and map VLAN 10 to VSAN 1.

[SwitchC] vlan 10

[SwitchC-vlan10] fcoe enable vsan 1

[SwitchC-vlan10] quit

4.

On Switch A, use the fcping command to ping Switch C. Identify whether Switch C is reachable.

[SwitchA] fcping fcid fffc03 vsan 1

FCPING fcid 0xfffc03: 128 data bytes, press CTRL_C to break.

Request time out

Request time out

Request time out

Request time out

Request time out

--- 0xfffc03 fcping statistics ---

5 packet(s) transmitted

0 packet(s) received

100.00% packet loss

The output shows that Switch A cannot reach Switch C.

5.

Use the fctracert command to identify the faulty node.

[SwitchA] fctracert fcid fffc03 vsan 1

Route present for: 0xfffc03, press CTRL_C to break

20:00:00:0b:46:00:02:82(0xfffc01)

20:00:00:05:30:00:18:db(0xfffc02)

Fctracert uncompleted: no route to destination port.

The output shows that Switch A can reach Switch B, but Switch B cannot reach Switch C. Therefore,
you can use the display fc routing-table command on Switch B to see whether there is a route to

Switch C.