Configuring an fc interface to reject incoming rcf, Requests, Enabling snmp notifications for the fabric or name – H3C Technologies H3C S5830V2 Series Switches User Manual
Page 60: Service module
49
Step Command
3.
Initiate the fabric reconfiguration.
domain restart [ disruptive ]
Configuring an FC interface to reject incoming RCF
requests
In a stable fabric, to avoid unnecessary disruptive reconfigurations, you can configure an FC interface to
reject the RCF requests received from a specific VSAN. With this feature, the interface on which an RCF
request is received replies with a reject message and is isolated.
To configure an FC interface to reject the received RCF requests:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter FC interface or VFC
interface view.
interface { fc | vfc } interface-number
N/A
3.
Configure the interface to
reject the received RCF
requests from a specific
VSAN.
fc domain rcf-reject vsan vsan-id
By default, an FC interface, FC
aggregate interface, or VFC
interface does not reject the
received RCF requests.
Enabling SNMP notifications for the fabric or name
service module
After you enable SNMP notifications for the fabric module or name service module, that module
generates notifications for important events and sends the notifications to the SNMP module. For more
information about SNMP notifications, see Network Management and Monitoring Configuration Guide.
To enable SNMP notifications:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enable SNMP
notifications for the fabric
module.
snmp-agent trap enable fc-fabric
[ domain-id-change | fabric-change ] *
By default, all SNMP notifications
are disabled for the fabric module.
3.
Enable SNMP
notifications for the name
service module.
snmp-agent trap enable
fc-name-service [ login | logout ] *
By default, all SNMP notifications
are disabled for the name service
module.