beautypg.com

Configuring an fc interface to reject incoming rcf, Requests, Enabling snmp notifications for the fabric or name – H3C Technologies H3C S5830V2 Series Switches User Manual

Page 60: Service module

background image

49

Step Command

3.

Initiate the fabric reconfiguration.

domain restart [ disruptive ]

Configuring an FC interface to reject incoming RCF

requests

In a stable fabric, to avoid unnecessary disruptive reconfigurations, you can configure an FC interface to

reject the RCF requests received from a specific VSAN. With this feature, the interface on which an RCF

request is received replies with a reject message and is isolated.
To configure an FC interface to reject the received RCF requests:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter FC interface or VFC

interface view.

interface { fc | vfc } interface-number

N/A

3.

Configure the interface to
reject the received RCF

requests from a specific

VSAN.

fc domain rcf-reject vsan vsan-id

By default, an FC interface, FC
aggregate interface, or VFC

interface does not reject the
received RCF requests.

Enabling SNMP notifications for the fabric or name

service module

After you enable SNMP notifications for the fabric module or name service module, that module

generates notifications for important events and sends the notifications to the SNMP module. For more

information about SNMP notifications, see Network Management and Monitoring Configuration Guide.
To enable SNMP notifications:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enable SNMP
notifications for the fabric

module.

snmp-agent trap enable fc-fabric
[ domain-id-change | fabric-change ] *

By default, all SNMP notifications
are disabled for the fabric module.

3.

Enable SNMP
notifications for the name

service module.

snmp-agent trap enable
fc-name-service [ login | logout ] *

By default, all SNMP notifications
are disabled for the name service
module.