H3C Technologies H3C S5830V2 Series Switches User Manual
Page 201
190
Principal switch running time information:
Priority: 1
Path Interface
Upstream Vfc10
The output shows that the domain configuration is complete on Switch A, and the principal switch assigns
domain ID 2 to Switch A.
# Display the domain ID list of VSAN 100.
[SwitchA] display fc domain-list vsan 100
Domain list of VSAN 100:
Number of domains: 2
Domain ID WWN
0x01(1) 48:33:43:2d:46:43:1C:1C [Principal]
0x02(2) 48:33:43:2d:46:43:1A:1A [Local]
The output shows that Switch C is elected as the principal switch, and the principal switch assigns domain
ID 1 to itself.
# Display the routing table information for Switch A.
[SwitchA] display fc routing-table vsan 100
Routing Table: VSAN 100
Destinations : 5 Routes : 5
Destination/mask Protocol Preference Cost Interface
0x010000/8 FSPF 20 100 Vfc10
0xfffc01/24 DIRECT 0 0 InLoop0
0xfffffa/24 DIRECT 0 0 InLoop0
0xfffffc/24 DIRECT 0 0 InLoop0
0xfffffd/24 DIRECT 0 0 InLoop0
The output shows that an FSPF route from Switch A to Switch C exists, with the outgoing interface VFC 10.
# Display the node login information for VSAN 100.
[SwitchA] display fc login vsan 100
Interface VSAN FCID Node WWN Port WWN
Vfc1 100 0x020000 21:01:00:1b:32:a0:fa:12 21:01:00:1b:32:a0:fa:11
# Display the brief information about the name server database in VSAN 100.
[SwitchA] display fc name-service database vsan 100
VSAN 100:
FCID Type PWWN(vendor) FC4-type:feature
0x010000 0x01(N) 10:00:00:05:30:00:25:a3 SCSI-FCP:Target
0x020000 0x01(N) 21:01:00:1b:32:a0:fa:11 SCSI-FCP:Initiator
Verifying the configuration on Switch C and Switch D
This example uses Switch C.
# Display the node login information for VSAN 100.
[SwitchC] display fc login vsan 100
Interface VSAN FCID Node WWN Port WWN
Vfc1 100 0x010000 10:00:00:05:30:00:25:a4 10:00:00:05:30:00:25:a3