H3C Technologies H3C S5830V2 Series Switches User Manual
Page 167
156
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr af2 group sp
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr af3 group sp
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr af4 group sp
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr ef group sp
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr cs6 group sp
[SwitchA-Ten-GigabitEthernet1/0/1] qos wrr cs7 group sp
[SwitchA-Ten-GigabitEthernet1/0/1] quit
6.
Configure FCoE:
# Configure the switch to operate in FCF mode.
[SwitchA] fcoe-mode fcf
# Enable the fabric configuration function for VSAN 100 (this step is optional because the fabric
configuration function is enabled by default).
[SwitchA] vsan 100
[SwitchA-vsan100] domain configure enable
# Configure the domain ID as 2 for the switch.
[SwitchA-vsan100] domain-id 2 preferred
Non-disruptive reconfiguration or isolating the switch may be performed. Continue?
[Y/N]:y
# Enable FSPF globally.
[SwitchA-vsan100] fspf enable
[SwitchA-vsan100] quit
# Create interface VFC 1.
[SwitchA] interface vfc 1
# Configure the mode of VFC 1 as F.
[SwitchA-Vfc1] fc mode f
# Bind VFC 1 to interface Ten-GigabitEthernet 1/0/1.
[SwitchA-Vfc1] bind interface ten-gigabitethernet 1/0/1
# Assign VFC 1 to VSAN 100 as a trunk port.
[SwitchA-Vfc1] port trunk vsan 100
[SwitchA-Vfc1] quit
# Create interface VFC 10.
[SwitchA] interface vfc 10
# Configure the mode of VFC 10 as E.
[SwitchA-Vfc10] fc mode e
# Bind VFC 10 to Layer 2 aggregate interface 1.
[SwitchA-Vfc10] bind interface bridge-aggregation 1
# Assign VFC 10 to VSAN 100 as a trunk port.
[SwitchA-Vfc10] port trunk vsan 100
# Enable FSPF for VFC 10.
[SwitchA-Vfc10] undo fspf silent vsan 100
[SwitchA-Vfc10] quit
# Enable FCoE for VLAN 4001, and map VLAN 4001 to VSAN 100.
[SwitchA] vlan 4001
[SwitchA-vlan4001] fcoe enable vsan 100
[SwitchA-vlan4001] quit