# Create interface VFC 10.

[SwitchC] interface vfc 10

# Configure the mode of VFC 10 as E.

[SwitchC-Vfc10] fc mode e

# Bind VFC 10 to Layer 2 aggregate interface 1.

[SwitchC-Vfc10] bind interface bridge-aggregation 1

# Assign VFC 10 to VSAN 100 as a trunk port.

[SwitchC-Vfc10] port trunk vsan 100

# Enable FSPF for VFC 10.

[SwitchC-Vfc10] undo fspf silent vsan 100

[SwitchC-Vfc10] quit

# Enable FCoE for VLAN 4001, and map VLAN 4001 to VSAN 100.

[SwitchC] vlan 4001

[SwitchC-vlan4001] fcoe enable vsan 100

[SwitchC-vlan4001] quit

# Enter the view of VSAN 100, and configure the members in the default zone to access each
other.

[SwitchC] vsan 100

[SwitchC-vsan100] zone default-zone permit

[SwitchC-vsan100] quit

Configuring Switch D

Configure Switch D is a similar way Switch C is configured. The differences are that:

The aggregate interface configured on Switch C is Layer 2 aggregate interface 1.

The aggregate interface configured on Switch D is Layer 2 aggregate interface 2.

Verifying the configuration

Verifying the configuration on Switch A and Switch B

This example uses Switch A.
# Display the domain information of VSAN 100.

[SwitchA] display fc domain vsan 100

Domain Information of VSAN 100:

Running time information:

State: Stable

Switch WWN: 48:33:43:2d:46:43:1A:1A

Fabric name: 48:33:43:2d:46:43:1C:1C

Priority: 128

Domain ID: 2

Configuration information:

Domain configure: Enabled

Domain auto-reconfigure: Disabled

Fabric name: 48:33:43:2d:46:43:1A:1A

Priority: 128

Domain ID: 2 (preferred)