Configuring switch d – H3C Technologies H3C S5830V2 Series Switches User Manual
Page 171
160
# Enable the fabric configuration function for VSAN 100 (this step is optional because the fabric
configuration function is enabled by default).
[SwitchC] vsan 100
[SwitchC-vsan100] domain configure enable
# Set the priority to 1 for the switch, so the switch can be elected as the principal switch.
[SwitchC-vsan100] priority 1
# Configure the domain ID as 1 for the switch.
[SwitchC-vsan100] domain-id 1 preferred
Non-disruptive reconfiguration or isolating the switch may be performed. Continue?
[Y/N]:y
# Enable FSPF globally.
[SwitchC-vsan100] fspf enable
[SwitchC-vsan100] quit
# Create interface VFC 1.
[SwitchC] interface vfc 1
# Configure the mode of VFC 1 as F.
[SwitchC-Vfc1] fc mode f
# Bind VFC 1 to interface Ten-GigabitEthernet 1/0/1.
[SwitchC-Vfc1] bind interface ten-gigabitethernet 1/0/1
# Assign VFC 1 to VSAN 100 as a trunk port.
[SwitchC-Vfc1] port trunk vsan 100
[SwitchC-Vfc1] quit
# Create interface VFC 10.
[SwitchC] interface vfc 10
# Configure the mode of VFC 10 as E.
[SwitchC-Vfc10] fc mode e
# Bind VFC 10 to Layer 2 aggregate interface 1.
[SwitchC-Vfc10] bind interface bridge-aggregation 1
# Assign VFC 10 to VSAN 100 as a trunk port.
[SwitchC-Vfc10] port trunk vsan 100
# Enable FSPF for VFC 10.
[SwitchC-Vfc10] undo fspf silent vsan 100
[SwitchC-Vfc10] quit
# Enable FCoE for VLAN 4001, and map VLAN 4001 to VSAN 100.
[SwitchC] vlan 4001
[SwitchC-vlan4001] fcoe enable vsan 100
[SwitchC-vlan4001] quit
# Enter the view of VSAN 100, and configure the members in the default zone to access each
other.
[SwitchC] vsan 100
[SwitchC-vsan100] zone default-zone permit
[SwitchC-vsan100] quit
Configuring Switch D
Configure Switch D is a similar way Switch C is configured. The differences are that: