H3C Technologies H3C S5830V2 Series Switches User Manual
Page 183
172
Non-disruptive reconfiguration or isolating the switch may be performed. Continue?
[Y/N]:y
# Enable FSPF globally for VSAN 200.
[SwitchA-vsan200] fspf enable
[SwitchA-vsan200] quit
# Create interface VFC 1.
[SwitchA] interface vfc 1
# Configure the mode of VFC 1 as F.
[SwitchA-Vfc1] fc mode f
# Bind VFC 1 to interface Ten-GigabitEthernet 1/0/1.
[SwitchA-Vfc1] bind interface ten-gigabitethernet 1/0/1
# Assign VFC 1 to VSAN 100 as a trunk port.
[SwitchA-Vfc1] port trunk vsan 100
[SwitchA-Vfc1] quit
# Create interface VFC 2.
[SwitchA] interface vfc 2
# Configure the mode of VFC 2 as F.
[SwitchA-Vfc2] fc mode f
# Bind VFC 2 to interface Ten-GigabitEthernet 2/0/1.
[SwitchA-Vfc2] bind interface ten-gigabitethernet 2/0/1
# Assign VFC 2 to VSAN 200 as a trunk port.
[SwitchA-Vfc2] port trunk vsan 200
[SwitchA-Vfc2] quit
# Create interface VFC 10.
[SwitchA] interface vfc 10
# Configure the mode of VFC 10 as E.
[SwitchA-Vfc10] fc mode e
# Bind VFC 10 to Layer 2 aggregate interface 1.
[SwitchA-Vfc10] bind interface bridge-aggregation 1
# Assign VFC 10 to VSAN 100 as a trunk port.
[SwitchA-Vfc10] port trunk vsan 100
# Enable FSPF for VFC 10.
[SwitchA-Vfc10] undo fspf silent vsan 100
[SwitchA-Vfc10] quit
# Create interface VFC 11.
[SwitchA] interface vfc 11
# Configure the mode of VFC 11 as E.
[SwitchA-Vfc11] fc mode e
# Bind VFC 11 to Layer 2 aggregate interface 2.
[SwitchA-Vfc11] bind interface bridge-aggregation 2
# Assign VFC 11 to VSAN 200 as a trunk port.
[SwitchA-Vfc11] port trunk vsan 200
# Enable FSPF for VFC 11.
[SwitchA-Vfc11] undo fspf silent vsan 200