Displaying and maintaining vsans, Vsan configuration examples, Vsan configuration example by using fc interfaces – H3C Technologies H3C S5830V2 Series Switches User Manual
Page 44: Network requirements, Requirements analysis
33
Displaying and maintaining VSANs
Execute display commands in any view.
Task Command
Display the member ports of the VSAN.
display vsan [ vsan-id ] port-member
VSAN configuration examples
VSAN configuration example by using FC interfaces
Network requirements
As shown in
, configure the VSANs to meet the following requirements:
•
Server A can read and write only the data of Disk A and Disk B.
•
Server B can read and write only the data of Disk C.
Figure 19 Network diagram
Requirements analysis
To meet the network requirements, perform the following tasks:
•
Divide the SAN into two VSANs, VSAN 10 and VSAN 20. Each VSAN contains a server and disk
devices that can exchange data.
•
Configure the two interfaces connecting Switch A to the servers to operate in F mode, and assign
the two interfaces as access ports to VSAN 10 and VSAN 20, respectively.
•
Configure the three interfaces connecting Switch B to the disk devices to operate in F mode, and
assign the three interfaces as access ports to VSAN 10 or VSAN 20.
•
Configure the interfaces connecting Switch A and Switch B to operate in E mode, configure the
trunk mode as on for the two interfaces, and assign the interfaces to VSANs 10 and 20 as trunk