beautypg.com

Verifying the configuration – H3C Technologies H3C S5830V2 Series Switches User Manual

Page 149

background image

138

[SwitchB] vlan 10

[SwitchB-vlan10] fcoe enable vsan 1

[SwitchB-vlan10] quit

# Configure a static route on Switch B.

[SwitchB] vsan 1

[SwitchB-vsan1] fc route-static 010000 8 vfc 1

[SwitchB-vsan1] quit

Verifying the configuration

Identify whether Switch A and Switch B can reach each other.
# On Switch A, use the fcping command to ping Switch B and identify whether Switch B is reachable.

[SwitchA] fcping fcid fffc02 vsan 1

FCPING fcid 0xfffc02: 128 data bytes, press CTRL_C to break.

Reply from 0xfffc02: bytes = 128 time = 23 ms

Reply from 0xfffc02: bytes = 128 time = 9 ms

Reply from 0xfffc02: bytes = 128 time = 19 ms

Reply from 0xfffc02: bytes = 128 time = 14 ms

Reply from 0xfffc02: bytes = 128 time = 25 ms

--- 0xfffc02 fcping statistics ---

5 packet(s) transmitted

5 packet(s) received

0.00% packet loss

round-trip min/avg/max = 9/18/25 ms