Configuring the fabric reconfiguration, Manually initiating the fabric reconfiguration – H3C Technologies H3C S5830V2 Series Switches User Manual
Page 59
48
Configuring the fabric reconfiguration
IMPORTANT:
The fabric reconfiguration function takes effects only when the fabric configuration function is enabled.
The fabric reconfiguration occurs in the case of a network reconstruction (for example, two fabrics are
merged) or external intervention (for example, the administrator uses a command to initiate
reconfiguration). The fabric reconfiguration triggers principal switch selection, domain ID assignment,
and FC address assignment throughout the fabric.
The fabric reconfiguration includes the following categories:
•
Disruptive reconfiguration—Floods the Reconfigure Fabric (RCF) frames throughout the fabric, and
notifies all switches to perform a disruptive reconfiguration. During the reconfiguration procedure,
each switch clears all data and performs renegotiation, and data transmission in the fabric is
disrupted.
•
Non-disruptive reconfiguration—Floods the Build Fabric (BF) frames throughout the fabric, and
notifies all switches to perform a nondisruptive reconfiguration. During the reconfiguration
procedure, each switch tries to save the last running data for its domain ID to remain unchanged.
Thus, data transmission in the fabric is not disrupted.
Depending on the triggering conditions, the fabric reconfiguration includes auto reconfiguration and
manual reconfiguration.
•
When two fabrics are merged:
{
The switches automatically perform a disruptive reconfiguration if the domain ID lists overlap.
{
The system automatically performs a nondisruptive reconfiguration if the principal switch
information of the two fabrics is different and the domain ID lists are not empty or overlapping.
{
You can manually initiate a disruptive reconfiguration to trigger the fabric reconfiguration if
ports are isolated and priority values of switches are modified.
•
When the principal switch in a fabric is down, the system automatically performs a nondisruptive
reconfiguration.
Configuring the auto fabric reconfiguration function
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter VSAN view.
vsan vsan-id
N/A
3.
Enable the auto fabric
reconfiguration function.
domain auto-reconfigure enable
By default, the auto fabric
reconfiguration function is disabled.
Manually initiating the fabric reconfiguration
Step Command
1.
Enter system view.
system-view
2.
Enter VSAN view.
vsan vsan-id