Step Command

Remarks

2.

Enable synchronous
information output.

info-center synchronous

By default, synchronous
information output is disabled.

Enabling duplicate log suppression

The output of consecutive duplicate logs at an interval of less than 30 seconds wastes system and network

resources.
With this feature enabled, the system starts a suppression period upon outputting a log:

During the suppression period, the system does not output logs that have the same module name,

level, mnemonic, location, and text as the previous log.

After the suppression period expires, if the same log continues to appear, the system outputs the
suppressed logs and the log number and starts another suppression period. The suppression period

is 30 seconds for the first time, 2 minutes for the second time, and 10 minutes for subsequent times.

If a different log is generated during the suppression period, the system aborts the current
suppression period, outputs suppressed logs and the log number and then the different log, and

starts another suppression period.

To enable duplicate log suppression:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enable duplicate log
suppression.

info-center logging suppress

duplicates

By default, duplicate log
suppression is disabled.

Disabling an interface from generating link up or

link down logs

By default, all interfaces generate link up or link down log information when the interface state changes.

In some cases, you might want to disable specific interfaces from generating this information. For
example:

You are concerned only about the states of some interfaces. In this case, you can use this function
to disable other interfaces from generating link up and link down log information.

An interface is unstable and continuously outputs log information. In this case, you can disable the
interface from generating link up and link down log information.

To disable an interface from generating link up or link down logs:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter interface view.

interface interface-type
interface-number

N/A