Monitor port: Ten-GigabitEthernet1/0/2

Remote probe VLAN: 2

# Display information about all mirroring groups on Device A.

[DeviceA] display mirroring-group all

Mirroring group 1:

Type: Remote source

Status: Active

Mirroring port:

Ten-GigabitEthernet1/0/1 Both

Remote probe VLAN: 2

Local port mirroring with multiple monitor ports configuration
example

Network requirements

As shown in

Figure 60

, configure port mirroring so the three data monitoring devices (Servers A, B, and

C) can monitor both the bidirectional traffic of the three departments.

Figure 60 Network diagram

Configuration procedure

# Create remote source group 1.

system-view

[DeviceA] mirroring-group 1 remote-source

# Configure Ten-GigabitEthernet 1/0/1 through Ten-GigabitEthernet 1/0/3 as source ports of the
remote source group.

[DeviceA] mirroring-group 1 mirroring-port ten-gigabitethernet 1/0/1 to

ten-gigabitethernet 1/0/3 both

# Configure an unused port (Ten-GigabitEthernet 1/0/5, for example) of Device A as the reflector port
of the remote source group.

[DeviceA] mirroring-group 1 reflector-port ten-gigabitethernet 1/0/5

Dept. A

Dept. B

Dept. C

DeviceA

ServerA

ServerB

ServerC

XGE1/0/3

XGE1/0/2

XGE1/0/1

XGE1/0/11

XGE1/0/12

XGE1/0/13