beautypg.com

Network requirements, Configuration procedure – H3C Technologies H3C S6300 Series Switches User Manual

Page 44

background image

31

The output shows that Device B has been synchronized to Device A, the clock stratum level of

Device B is 3, and that of Device A is 2.
# Display IPv6 NTP association information for Device B.

[DeviceB] display ntp-service ipv6 sessions

Notes: 1 source(master), 2 source(peer), 3 selected, 4 candidate, 5 configured.

Source: [12345]3000::34

Reference: 127.127.1.0 Clock stratum: 2

Reachabilities: 15 Poll interval: 64

Last receive time: 19 Offset: 0.0

Roundtrip delay: 0.0 Dispersion: 0.0

Total sessions : 1

The output shows that an association has been set up between Device B and Device A.

NTP symmetric active/passive mode configuration

example

Network requirements

As shown in

Figure 10

, Device C has a clock more accurate than Device A.

Set the local clock of Device A as a reference source, with the stratum level 3.

Set the local clock Device C as a reference source, with the stratum level 2.

Configure Device B to operate in client mode and specify Device A as the NTP server of Device B.

Configure Device C to operate in symmetric-active mode and specify Device B as the passive peer
of Device C.

Figure 10 Network diagram

Configuration procedure

1.

Set the IP address for each interface as shown in

Figure 10

. (Details not shown.)

2.

Configure Device A: