Network requirements, Configuration procedure – H3C Technologies H3C S6300 Series Switches User Manual
Page 44
31
The output shows that Device B has been synchronized to Device A, the clock stratum level of
Device B is 3, and that of Device A is 2.
# Display IPv6 NTP association information for Device B.
[DeviceB] display ntp-service ipv6 sessions
Notes: 1 source(master), 2 source(peer), 3 selected, 4 candidate, 5 configured.
Source: [12345]3000::34
Reference: 127.127.1.0 Clock stratum: 2
Reachabilities: 15 Poll interval: 64
Last receive time: 19 Offset: 0.0
Roundtrip delay: 0.0 Dispersion: 0.0
Total sessions : 1
The output shows that an association has been set up between Device B and Device A.
NTP symmetric active/passive mode configuration
example
Network requirements
As shown in
, Device C has a clock more accurate than Device A.
•
Set the local clock of Device A as a reference source, with the stratum level 3.
•
Set the local clock Device C as a reference source, with the stratum level 2.
•
Configure Device B to operate in client mode and specify Device A as the NTP server of Device B.
•
Configure Device C to operate in symmetric-active mode and specify Device B as the passive peer
of Device C.
Figure 10 Network diagram
Configuration procedure
1.
Set the IP address for each interface as shown in
. (Details not shown.)
2.
Configure Device A: