beautypg.com

H3C Technologies H3C S6300 Series Switches User Manual

Page 54

background image

41

Reference clock ID: 165.84.121.65

Leap indicator: 00

Clock jitter: 0.000977 s

Stability: 0.000 pps

Clock precision: 2^-10

Root delay: 0.00000 ms

Root dispersion: 8.00578 ms

Reference time: d0c60680.9754fb17 Wed, Dec 29 2010 19:12:00.591

The output shows that Switch D has been synchronized to Switch C, the clock stratum level of

Switch D is 3, and that of Switch C is 2.
# Display NTP association information for Switch D.

[SwitchD-Vlan-interface2] display ntp-service ipv6 sessions

Notes: 1 source(master), 2 source(peer), 3 selected, 4 candidate, 5 configured.

Source: [1234]3000::2

Reference: 127.127.1.0 Clock stratum: 2

Reachabilities: 111 Poll interval: 64

Last receive time: 23 Offset: -0.0

Roundtrip delay: 0.0 Dispersion: 0.0

Total sessions : 1

The output shows that an association has been set up between Switch D and Switch C.

5.

Configure Switch B:
Because Switch A and Switch C are on different subnets, you must enable the IPv6 multicast
functions on Switch B before Switch A can receive IPv6 multicast messages from Switch C.
# Enable IPv6 multicast functions.

system-view

[SwitchB] ipv6 multicast routing

[SwitchB-mrib6] quit

[SwitchB] interface vlan-interface 2

[SwitchB-Vlan-interface2] ipv6 pim dm

[SwitchB-Vlan-interface2] quit

[SwitchB] vlan 3

[SwitchB-vlan3] port ten-gigabitethernet 1/0/1

[SwitchB-vlan3] quit

[SwitchB] interface vlan-interface 3

[SwitchB-Vlan-interface3] mld enable

[SwitchB-Vlan-interface3] mld static-group ff24::1

[SwitchB-Vlan-interface3] quit

[SwitchB] mld-snooping

[SwitchB-mld-snooping] quit

[SwitchB] interface ten-gigabitethernet 1/0/1

[SwitchB-Ten-GigabitEthernet1/0/1] mld-snooping static-group ff24::1 vlan 3

6.

Configure Switch A:
# Enable the NTP service.

system-view

[SwitchA] ntp-service enable