beautypg.com

H3C Technologies H3C S6300 Series Switches User Manual

Page 212

background image

199

Step Command

Remarks

3.

Configure an event in
the policy.

Configure a CLI event:

event cli { async [ skip ] | sync } mode

{ execute | help | tab } pattern
regular-exp

Configure a hotplug event:

event hotplug slot slot-number

Configure an interface event:

event interface interface-type

interface-number monitor-obj
monitor-obj start-op start-op start-val

start-val restart-op restart-op restart-val

restart-val [ interval interval ]

Configure a process event:

event process { exception | restart |

shutdown | start } [ name process-name
[ instance instance-id ] ] [ slot

slot-number ]

Configure an SNMP event:

event snmp oid oid monitor-obj { get |

next } start-op start-op start-val start-val

restart-op restart-op restart-val
restart-val [ interval interval ]

Configure an SNMP_Notification event:

event snmp-notification oid oid oid-val
oid-val op op [ drop ]

Configure a Syslog event:

event syslog priority level msg msg
occurs times period period

By default, a monitor policy does
not contain an event.
You can configure only one event

in a monitor policy. If the monitor
policy already contains an event,

the new event overrides the old

event.

4.

Configure the actions
to take when the event

occurs.

Configure the action to execute a

command:

action number cli command-line

Configure a reboot action:

action number reboot [ slot slot-number ]

Configure a logging action:

action number syslog priority level

facility local-number msg msg

Configure an active/standby switchover

action:

action number switchover

By default, a monitor policy does
not contain any actions.
Repeat this step to add a
maximum of 232 actions to the

policy.
You can reference a variable

name in the $variable_name
format instead of specifying a

value for an argument when you

define an action.

5.

(Optional.) Assign a
user role to the policy. user-role role-name

By default, a monitor policy
contains user roles that its creator

had at the time of policy creation.
A monitor policy supports a
maximum of 64 valid user roles.

User roles added after this limit is

reached do not take effect.

6.

(Optional.) Configure
the policy runtime.

running-time time

The default runtime is 20
seconds.