beautypg.com

Configuration procedure – H3C Technologies H3C S6300 Series Switches User Manual

Page 56

background image

43

Figure 15 Network diagram

Configuration procedure

1.

Set the IP address for each interface as shown in

Figure 15

. (Details not shown.)

2.

Configure Device A:
# Enable the NTP service.

system-view

[DeviceA] ntp-service enable

# Specify the local clock as the reference source, with the stratum level 2.

[DeviceA] ntp-service refclock-master 2

3.

Configure Device B:
# Enable the NTP service.

system-view

[DeviceB] ntp-service enable

# Enable NTP authentication on Device B.

[DeviceB] ntp-service authentication enable

# Set an authentication key, and input the key in plain text.

[DeviceB] ntp-service authentication-keyid 42 authentication-mode md5 simple

aNiceKey

# Specify the key as a trusted key.

[DeviceB] ntp-service reliable authentication-keyid 42

# Specify Device A as the NTP server of Device B, and associate the server with key 42.

[DeviceB] ntp-service unicast-server 1.0.1.11 authentication-keyid 42

Before Device B can synchronize its clock to that of Device A, enable NTP authentication for

Device A.

4.

Configure NTP authentication on Device A:
# Enable NTP authentication.

[DeviceA] ntp-service authentication enable

# Set an authentication key, and input the key in plain text.

[DeviceA] ntp-service authentication-keyid 42 authentication-mode md5 simple

aNiceKey

# Specify the key as a trusted key.

[DeviceA] ntp-service reliable authentication-keyid 42

5.

Verify the configuration:
# Display the NTP status of Device B after clock synchronization.

[DeviceB] display ntp-service status

Clock status: synchronized

Clock stratum: 3

System peer: 1.0.1.11

Local mode: client