H3C Technologies H3C S6300 Series Switches User Manual
Page 83
70
2.
Configure Device B:
# Specify the PTP standard as IEEE 802.1AS.
[DeviceB] ptp profile 802.1AS
# Specify the clock node type as P2PTC.
[DeviceB] ptp mode p2ptc
# Enable PTP for Ten-GigabitEthernet 1/0/1.
[DeviceB] interface ten-gigabitethernet 1/0/1
[DeviceB-Ten-GigabitEthernet1/0/1] ptp enable
[DeviceB-Ten-GigabitEthernet1/0/1] quit
# Enable PTP for Ten-GigabitEthernet 1/0/2.
[DeviceB] interface ten-gigabitethernet 1/0/2
[DeviceB-Ten-GigabitEthernet1/0/2] ptp enable
[DeviceB-Ten-GigabitEthernet1/0/2] quit
3.
Configure Device C:
# Specify the PTP standard as IEEE 1588 802.1AS.
[DeviceC] ptp profile 802.1AS
# Specify the clock node type as OC.
[DeviceC] ptp mode oc
# Enable PTP on Ten-GigabitEthernet 1/0/1.
[DeviceC] interface ten-gigabitethernet 1/0/1
[DeviceC-Ten-GigabitEthernet1/0/1] ptp enable
[DeviceC-Ten-GigabitEthernet1/0/1] quit
4.
Verify the configuration:
When the network is stable, display PTP clock information by using the display ptp clock command,
and display brief PTP statistics on an interface by using the display ptp interface brief command.
# Display PTP clock information on Device A.
[DeviceA] display ptp clock
PTP profile : IEEE 802.1AS
PTP mode : OC
Slave only : No
Clock ID : 000FE2-FFFE-FF0000
Clock type : Local
Clock domain : 0
Number of PTP ports : 1
Priority1 : 246
Priority2 : 248
Clock quality :
Class : 248
Accuracy : 254
Offset (log variance) : 16640
Offset from master : 0 (ns)
Mean path delay : 0 (ns)
Steps removed : 0
Local clock time : Sun Jan 15 20:57:29 2011