beautypg.com

Configuring bidirectional control detection – H3C Technologies H3C S12500-X Series Switches User Manual

Page 68

background image

54

# Configure Switch A.

system-view

[SwitchA] rip 1

[SwitchA-rip-1] version 2

[SwitchA-rip-1] undo summary

[SwitchA-rip-1] network 192.168.1.0

[SwitchA-rip-1] network 101.1.1.0

[SwitchA-rip-1] peer 192.168.2.2

[SwitchA-rip-1] undo validate-source-address

[SwitchA-rip-1] import-route static

[SwitchA-rip-1] quit

[SwitchA] interface vlan-interface 100

[SwitchA-Vlan-interface100] rip bfd enable

[SwitchA-Vlan-interface100] quit

[SwitchA] rip 2

[SwitchA-rip-2] version 2

[SwitchA-rip-2] undo summary

[SwitchA-rip-2] network 192.168.3.0

[SwitchA-rip-2] quit

# Configure Switch C.

system-view

[SwitchC] rip 1

[SwitchC-rip-1] version 2

[SwitchC-rip-1] undo summary

[SwitchC-rip-1] network 192.168.2.0

[SwitchC-rip-1] network 192.168.4.0

[SwitchC-rip-1] network 100.1.1.0

[SwitchC-rip-1] peer 192.168.1.1

[SwitchC-rip-1] undo validate-source-address

[SwitchC-rip-1] import-route static

[SwitchC-rip-1] quit

[SwitchC] interface vlan-interface 200

[SwitchC-Vlan-interface200] rip bfd enable

[SwitchC-Vlan-interface200] quit

# Configure Switch D.

system-view

[SwitchD] rip 1

[SwitchD-rip-1] version 2

[SwitchD-rip-1] undo summary

[SwitchD-rip-1] network 192.168.3.0

[SwitchD-rip-1] network 192.168.4.0

3.

Configure BFD parameters:
# Configure Switch A.

[SwitchA] bfd session init-mode active

[SwitchA] interface vlan-interface 100

[SwitchA-Vlan-interface100] bfd min-transmit-interval 500

[SwitchA-Vlan-interface100] bfd min-receive-interval 500

This manual is related to the following products: