BFD for IPv6 IS-IS configuration example

683B

Network requirements

As shown in

1238H

Figure 85

, configure IPv6 IS-IS on Switch A and Switch B so that they can reach other.

Enable BFD on VLAN-interface 10 of Switch A and Switch B. After the link between Switch B and
the Layer-2 switch fails, BFD can quickly detect the failure and notify IPv6 IS-IS of the failure. Then

Switch A and Switch B communicate through Switch C.

Figure 85 Network diagram

Device Interface IPv6

address

Device

Interface

IPv6 address

Switch A

Vlan-int10

2001::1/64

Switch B

Vlan-int10 2001::2/64

Vlan-int11

2001:2::1/64

Vlan-int13

2001:3::2/64

Switch C

Vlan-int11

2001:2::2/64

Vlan-int13

2001:3::1/64

684B

Configuration procedure

1.

Configure IPv6 addresses for interfaces. (Details not shown.)

2.

Configure IPv6 IS-IS:
# Configure Switch A.

system-view

[SwitchA] isis 1

[SwitchA-isis-1] is-level level-1

[SwitchA-isis-1] network-entity 10.0000.0000.0001.00

[SwitchA-isis-1] ipv6 enable

[SwitchA-isis-1] quit

[SwitchA] interface vlan-interface 10

[SwitchA-Vlan-interface10] isis ipv6 enable 1

[SwitchA-Vlan-interface10] quit

[SwitchA] interface vlan-interface 11

[SwitchA-Vlan-interface11] isis ipv6 enable 1

[SwitchA-Vlan-interface11] quit

# Configure Switch B.

system-view

[SwitchB] isis 1

[SwitchB-isis-1] is-level level-1