Verifying the configuration – H3C Technologies H3C S12500-X Series Switches User Manual
Page 361
347
[SwitchB] bfd session init-mode active
[SwitchB] interface vlan-interface 10
[SwitchB-Vlan-interface10] ospfv3 bfd enable
[SwitchB-Vlan-interface10] bfd min-transmit-interval 500
[SwitchB-Vlan-interface10] bfd min-receive-interval 500
[SwitchB-Vlan-interface10] bfd detect-multiplier 6
679B
Verifying the configuration
# Display the BFD information on Switch A.
Total Session Num: 1 Init Mode: Active
IPv6 Session Working Under Ctrl Mode:
Local Discr: 1441 Remote Discr: 1450
Source IP: FE80::20F:FF:FE00:1202 (link-local address of VLAN-interface 10 on
Switch A)
Destination IP: FE80::20F:FF:FE00:1200 (link-local address of VLAN-interface 10 on
Switch B)
Session State: Up Interface: Vlan10
Hold Time: 2319ms
# Display routes destined for 2001:4::0/64 on Switch A.
Summary Count : 1
Destination: 2001:4::/64 Protocol : OSPFv3
NextHop : FE80::20F:FF:FE00:1200 Preference: 10
Interface : Vlan10 Cost : 1
The output information shows that Switch A communicates with Switch B through VLAN-interface 10. The
link over VLAN-interface 10 fails.
# Display routes to 2001:4::0/64 on Switch A.
Summary Count : 1
Destination: 2001:4::/64 Protocol : OSPFv3
NextHop : FE80::BAAF:67FF:FE27:DCD0 Preference: 10
Interface : Vlan11 Cost : 2
The output shows that Switch A communicates with Switch B through VLAN-interface 11.