beautypg.com

H3C Technologies H3C S12500-X Series Switches User Manual

Page 31

background image

17

138B

BFD for static routes configuration example (indirect next hop)

451B

Network requirements

In

897H

Figure 4

, Switch A has a route to interface Loopback 1 (2.2.2.9/32) on Switch B, with the output

interface VLAN-interface 10. Switch B has a route to interface Loopback 1 (1.1.1.9/32) on Switch A, with

the output interface VLAN-interface 12. Switch D has a route to 1.1.1.9/32, with the output interface
VLAN-interface 10, and a route to 2.2.2.9/32, with the output interface VLAN-interface 12.
Configure a static route to subnet 120.1.1.0/24 on Switch A, and configure a static route to subnet

121.1.1.0/24 on Switch B. Enable BFD for both routes. Configure a static route to subnet 120.1.1.0/24 and

a static route to subnet 121.1.1.0/24 on both Switch C and Switch D. When the link between Switch A and
Switch B through Switch D fails, BFD can detect the failure immediately and inform Switch A and Switch

B to communicate through Switch C.

Figure 4 Network diagram

Device Interface IP

address

Device

Interface

IP address

Switch A

Vlan-int10

12.1.1.1/24

Switch B

Vlan-int12 11.1.1.1/24

Vlan-int11

10.1.1.102/24

Vlan-int13

13.1.1.1/24

Loop1

1.1.1.9/32

Loop1

2.2.2.9/32

Switch C

Vlan-int11

10.1.1.100/24

Switch D

Vlan-int10 12.1.1.2/24

Vlan-int13

13.1.1.2/24

Vlan-int12

11.1.1.2/24

452B

Configuration procedure

1.

Configure IP addresses for interfaces. (Details not shown.)

2.

Configure static routes and BFD:
# Configure static routes on Switch A and enable BFD control mode for the static route that
traverses Switch D.

system-view

[SwitchA] bfd multi-hop min-transmit-interval 500

[SwitchA] bfd multi-hop min-receive-interval 500

[SwitchA] bfd multi-hop detect-multiplier 9

[SwitchA] ip route-static 120.1.1.0 24 2.2.2.9 bfd control-packet bfd-source 1.1.1.9

[SwitchA] ip route-static 120.1.1.0 24 vlan-interface 11 10.1.1.100 preference 65

[SwitchA] quit

# Configure static routes on Switch B and enable BFD control mode for the static route that
traverses Switch D.

system-view