Specifying spf calculation interval, Specifying the lsa generation interval, Configuring a dr priority for an interface – H3C Technologies H3C S12500-X Series Switches User Manual
Page 343
329
404B
Specifying SPF calculation interval
LSDB changes result in SPF calculations. When the topology changes frequently, a large amount of
network and router resources are occupied by SPF calculation. You can adjust the SPF calculation
interval to reduce the impact.
When network changes are not frequent, the minimum-interval is adopted. If network changes become
frequent, the SPF calculation interval is incremented by incremental-interval × 2
n-2
(n is the number of
generation times) each time an SPF calculation occurs until the maximum-interval is reached.
To configure SPF calculation interval:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter OSPFv3 view.
ospfv3 [ process-id | vpn-instance
vpn-instance-name ] *
N/A
3.
Specify the SPF
calculation interval.
spf-schedule-interval maximum-interval
[ minimum-interval
[ incremental-interval ] ]
By default:
•
The maximum interval is 5
seconds.
•
The minimum interval is 50
milliseconds.
•
The incremental interval is 200
milliseconds.
405B
Specifying the LSA generation interval
You can adjust the LSA generation interval to protect network resources and routers from being over
consumed by frequent network changes.
When network changes are not frequent, LSAs are generated at the minimum-interval. If network
changes become frequent, the LSA generation interval is incremented by incremental-interval × 2
n-2
(n is
the number of generation times) each time an LSA generation occurs until the maximum-interval is
reached.
To configure the LSA generation interval:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter OSPFv3 view.
ospfv3 [ process-id | vpn-instance
vpn-instance-name ] *
N/A
3.
Configure the LSA
generation interval.
lsa-generation-interval
maximum-interval [ minimum-interval
[ incremental-interval ] ]
By default, the maximum interval is 5
seconds, the minimum interval is 0
milliseconds, and the incremental
interval is 0 milliseconds.
406B
Configuring a DR priority for an interface
The router priority is used for DR election. Interfaces having the priority 0 cannot become a DR or BDR.