302

The output shows that Switch A communicates with Switch B through VLAN-interface 11.

368B

BFD for IPv6 static routes configuration example (indirect next
hop)

659B

Network requirements

In

1182H

Figure 76

, Switch A has a route to interface Loopback 1 (2::9/128) on Switch B, with the output

interface being VLAN-interface 10. Switch B has a route to interface Loopback 1 (1::9/128) on Switch A,

with the output interface being VLAN-interface 12. Switch D has a route to 1::9/128, with the output

interface being VLAN-interface 10, and a route to 2::9/128, with the output interface being
VLAN-interface 12.
Configure an IPv6 static route to subnet 120::/64 on Switch A, and configure an IPv6 static route to

subnet 121::/64 on Switch B. Enable BFD for both routes. Configure an IPv6 static route to subnet

120::/64 and an IPv6 static route to subnet 121::/64 on both Switch C and Switch D. When the link
between Switch A and Switch B through Switch D fails, BFD can detect the failure immediately and

Switch A and Switch B can communicate through Switch C.

Figure 76 Network diagram

Device Interface IPv6

address

Device

Interface

IPv6 address

Switch A

Vlan-int10

12::1/64

Switch B

Vlan-int12 11::2/64

Vlan-int11

10::102/64

Vlan-int13

13::1/64

Loop1

1::9/128

Loop1

2::9/128

Switch C

Vlan-int11

10::100/64

Switch D

Vlan-int10 12::2/64

Vlan-int13

13::2/64 Vlan-int12

11::1/64

660B

Configuration procedure

1.

Configure IPv6 addresses for interfaces. (Details not shown.)

2.

Configure IPv6 static routes and BFD:
# Configure IPv6 static routes on Switch A and enable BFD control packet mode for the IPv6 static
route that traverses Switch D.

system-view

[SwitchA] interface loopback 1

[SwitchA-LoopBack1] bfd min-transmit-interval 500

[SwitchA-LoopBack1] bfd min-receive-interval 500

[SwitchA-LoopBack1] bfd detect-multiplier 9

[SwitchA-LoopBack1] quit

Switch A

Switch B

Switch C

BFD

Vlan-int10

Vl

an-

int11

Vlan-int11

Vlan-int13

Vlan-

int13

Vlan-int10

121::/64

120::/64

Switch D

Vlan-int12

Vlan-int12

Loop1

1::9/128

Loop1

2::9/128