beautypg.com

Comtech EF Data SNM-1001L User Manual

Page 88

background image

SNM-1001L Satellite Modem

Revision 1

Front Panel Operation

MN/SNM1001L.IOM

4–24

FUNCTION SELECT: CONFIGURATION: DEMODULATOR:

REACQUISITION

REACQUISITION

0 SECONDS


Programs the sweep reacquisition mode time duration. This is the time that the modem will
remain in a narrow sweep after loss of acquisition. After this timer runs out, the modem will
return to the normal acquisition sweep. The reacquisition time is 0 to 999 seconds.

Upon entry, the current programmed setting is displayed with a flashing cursor on the first
character. Press [

←] or [→] to move the flashing cursor. Press [↑] or [↓] to increment or

decrement the digit at the flashing cursor. Select the number of seconds desired for the
reacquisition mode. Press to execute the change.

FUNCTION SELECT: CONFIGURATION: DEMODULATOR:
LNB POWER

LNB POWER

OFF


Programs the LNB Power On or Off. The LNB voltage is transmitted up the center conductor of
the RF-IF connector.

Upon entry, the current status of the descrambler is displayed. Press [

↑] or [↓] to make the

selection. Press to execute the change.

FUNCTION SELECT: CONFIGURATION: DEMODULATOR:
LNB VOLTAGE

LNB VOLTAGE

13 VDC


Programs the LNB Power at 13, 18, or 24 VDC.

Upon entry, the current status of the descrambler is displayed. Press [

↑] or [↓] to make the

selection. Press to execute the change.