beautypg.com

Response message structure (buc to idu), Power class, 2 response message structure (buc to idu) – Comtech EF Data SNM-1001L User Manual

Page 225: 3 power class, Data field definitions, Includes all power levels for c- and ku-bands

background image

SNM-1001L Satellite Modem

Revision 1

BUC FSK Communications

MN/SNM1001L.IOM

13–3

13.2.2

Response Message Structure (BUC to IDU)

Byte

Name

Description

Value

1

Address

Address of BUC shifted left by 4

0x10 to 0xf0

2

Level Byte 1

MSbyte of TX output power

3

Level Byte 2

LSbyte of TX output power

4 Temperature Temperature in

°C

5

Status Byte 1

Bit 0: Temperature out-of-range
Bit 1: PLL out-of-lock
Bit 2: Checksum error

Bit 3: TX Status
Bits 4 thru 7: Power Class

1: OOR, 0: Normal
1: OOL, 0: Normal
1: error in command
message, 0: Normal

1: TX ON, 0: TX Off
0x1 to 0xf

6

Status Byte 2

Bits 0 – 3: Not used
Bits 4 –7: Software version

0xAA
0x0 to 0xf

7

Checksum

Algebraic sum of bytes 1 - 6

Data Field Definitions

TX Power Level

Unsigned integer in 1/100 dBm

Carrier Frequency

Unsigned integer in MHz.

Termperature

Signed character in

°C

13.3 Power

Class

Includes all power levels for C- and Ku-Bands.

Value

Power

0x1 2

watt

0x2 4

watt

0x3 5

watt

0x4 8

watt

0x5 10

watt

0x6 16

watt

0x7 20

watt

0x8 25

watt

0x9 40

watt

0xa 60

watt