B.4.3 odu configuration status – Comtech EF Data SNM-1001L User Manual
Page 293
SNM-1001L Satellite Modem
Revision 1
Remote Control Operation MN/SNM1001L.IOM
B–19
The Interface configuration status command causes a block of
data to be returned by the addressed MODEM. The block
reflects the current configuration of the interface. Additional
configuration status of new options and features will always be
appended to the end.
Notes:
1. Data is only returned for TX D&I Overhead.
2. Data is only returned for RX D&I Overhead.
3. Data is only returned for TX IDR Overhead.
4. Data is only returned for RX IDR Overhead.
5. Data is only returned for TX ASYNC Overhead.
6. Data is only returned for RX ASYNC Overhead.
7 Not
Used.
thru
14.
Current
Receive
Reed
Solomon N/
K and
Interleaver
value
Command:
Response:
Where: nn = N value, kkk = K value and ii = Interleaver value.
Descrambler
Type
Command:
Response:
Where xxxxxxxxxxxx = EFD MOD V.35, INTELSAT V.35, FDC
MOD V.35, ITU V.35 or OFF.
B.4.3
ODU Configuration Status
Outdoor Unit
Status
Command:
Response:
CURRENT_xxx'cr'
VOLTAGE_xxx'cr'
TEMP_xxx’cr’
PLL_xxx’cr’
CKSUM_xxx’cr’
SFLT_xx'cr''lf']
Current (FLT/OK)
Voltage (FLT/OK)
Temperature (FLT/OK)
Phase Lock Loop (FLT/OK)
Checksum (FLT/OK)
Number of stored faults logged (0 to 10)
Outdoor Unit
Temperature
Command:
Response:
ODU_sxx_yyy'cr’’lf']
Where s = + or – sign, xx = 0 to 99 degree in C and yyy = OK
or OOR (Out of Range).
Outdoor Unit
Phase Lock
Loop
Command:
Response:
Where xxxxxxxx = UNLOCKED or OK.
Outdoor Unit
Software
Version
Command:
Response:
Where xx = 0 to 15.
Outdoor Unit
Power Class
Command:
Response:
Where xx = 2 to 60 Watts
Outdoor Unit
Address
Command:
Response:
Where xx = 1 to 15.
Outdoor Unit
TX Output
Command:
Response:
Where xxx = ON or OFF.
Outdoor Unit
Power
Leveling
Command:
Response:
Where xxx = ON or OFF.