beautypg.com

Aupc parameters, Aupc with reed-solomon option, Turbo aupc – Comtech EF Data SNM-1001L User Manual

Page 270: A.13.1 aupc parameters, A.13.2 aupc with reed-solomon option, A.13.3 turbo aupc

background image

SNM-1001L Satellite Modem

Revision 1

Specifications

MN/SNM1001L.IOM

A–32

A.13.1 AUPC

Parameters

Table A-10. AUPC Parameters

Local Automatic Uplink Power
Control (AUPC)

AUPC functions are available through the use of the optional . The
operator can select local AUPC to be enabled or disabled.

AUPC Power Levels

The operator can select from 0 to -40 dBm in 0.5 dBm steps, for the
nominal, minimum, and maximum transmit power levels. Changes in the
power level shall not interrupt the carrier.

AUPC Target Noise Level

The operator can select the Eb/N0 target setpoint from 3.2 to 16.0 dB in
0.1 dBm steps.

AUPC Tracking Rate

The operator can select the maximum tracking rate from 0.5 to 6.0
dBm/minute in 0.5 dBm/minute steps.

AUPC Carrier Loss Action

The operator can select transmit power level to Maximum, Nominal, or
Hold for both local and remote carrier loss.
Note: Local carrier loss has priority over remote carrier loss.

Remote AUPC

The operator can select remote AUPC to be enabled or disabled. The
operator can also select a remote transmit 2047 test pattern and a remote
baseband loopback to be enabled or disabled. The operator can monitor
the remote AUPC 2047 bit error rate.

A.13.2

AUPC with Reed-Solomon Option

The AUPC function is supported, when the Reed-Solomon card is installed.

Note: The ASYNC requires the overhead card.

A.13.3 Turbo

AUPC

Self monitoring AUPC is provided.