Card #3 options, Local modem aupc off – Comtech EF Data SNM-1001L User Manual
Page 153
SNM-1001L Satellite Modem
Revision 1
Front Panel Operation
MN/SNM1001L.IOM
4–89
FUNCTION SELECT: UTILITY: MODEM TYPE: CARD #3 OPTIONS
(CONDITIONAL)
CARD #3 OPTIONS
-
(Status Only.) Menu appears when Card #3 is installed.
Displays one of the following:
REED SOLOMON 02 LIST:
INTELSAT
AUPC
REED SOLOMON 03 LIST:
INTELSAT
AUPC
TURBO LIST:
AUPC
(- or +)
(- or +)
(- or +)
(- or +)
(- or +)
FUNCTION SELECT: UTILITY: MODEM TYPE: LOCAL MODEM AUPC
LOCAL MODEM AUPC
OFF
Selecting Local Modem AUPC = ON enables the Configuration: Local AUPC: menu where
programming for self-monitoring AUPC with one modem or remote AUPC between two modems
is performed. These modes automatically adjust the TX Power Level from the modulator to
compensate for rain fades.
The self monitoring does not require the AUPC Option and Reed-Solomon cards installed to
operate.
AUPC between two modems does require either the ASYNC/AUPC option and the Overhead
Card or the AUPC option and the Reed-Solomon cards.
Notes:
1. When the Reed-Solomon card with AUPC option is installed, select AUPC from the
Modem Type menu (under Utility: Modem Type menu) when AUPC between two
modems is needed.
2. The Modem must be configured for Duplex operation and the demodulator locked to the
modulator signal.