Revision 1

Remote Control Operation MN/SNM1001L.IOM

B–28

Bulk Consol.
Status
(continued)


Parameter
Number

Parameter Name
(Command Reference)


Description



























(Note 16)

17

18

19

20

21

22

23

24

25
26


27



28

29


30

31

32

33

34


Demodulator rate
(ref. 'DR_' command).
Demodulator preset A
(ref. 'ADRA_' command).
Demodulator preset B assignment
(ref. 'ADRB_' command).
Demodulator preset C assignment
(ref. 'ADRC_' command).
Demodulator preset D assignment
(ref. 'ADRD_' command).
Demodulator preset V assignment
(ref. 'ADRV_' command).
Descrambler enable
(ref. 'DE_' command).
Differential decoder
(ref. 'DDEC_' command).
Reserved null field
IF Loopback
(ref. 'IFL_' command).

Sweep center frequency
(ref. 'SCF_' command).

Sweep width range
(ref. 'SWR_' command).

Sweep reacquisition
(ref. 'SR_' command).
BER threshold
(ref. 'BERT_' command).
Demodulator type
(ref. 'DT_' command).
Demodulator decoder type
(ref. 'DDT_' command).
Transmit clock source
(ref. 'TC_' command).
External reference frequency
(ref. 'ERF_' command).

p17 = nnnn_mmmm.mmm, code rate/data rate in kbps.

p18 = nnnn_mmmm.mmm, code rate/data rate in kbps.

p19 = nnnn_mmmm.mmm, code rate/data rate in kbps.

p20 = nnnn_mmmm.mmm, code rate/data rate in kbps.

p21 = nnnn_mmmm.mmm, code rate/data rate in kbps.

p22 = nnnn_mmmm.mmm, code rate/data rate in kbps.

p23 = n, where 'n' is '0' (off) or '1' (on).

p24 = n, where 'n' is '0' (off) or '1' (on).


P26 = n, where 'n' is '0' (off) or '1' (on).


p27 = snnnnn, sweep center frequency in Hertz.



p28 = nnnnnn, sweep range in Hertz.


p29 = nnn, reacquisition time in seconds.

p30 = xxxx, BER threshold.

p31 = n, where 'n' is '0' (EFD), '1' (INTL), '3' (FDC), or '4'
(CSC).
p32 = n, where 'n' is '0' (SEQ), '1' (VIT).

p33 = n, where 'n' is '0' (INT), '1' (REF), '2' (EXT), or 6
(DATA).
p34 = nnnnn.n, external reference frequency in kHz.