Error performance, B.4.2 error performance – Comtech EF Data SNM-1001L User Manual

Page 295

background image

SNM-1001L Satellite Modem

Revision 1

Remote Control Operation MN/SNM1001L.IOM

B–21

Common
Equipment
Status

Command:
Response:

>add/CES_'cr'
M&C_xxx'cr'
INT_xxx'cr'
BAT_xxx'cr'
+5_xxx'cr'
+12_xxx'cr'
-12_xxx'cr'
ST_xxx'cr'
MODE_xxxxxx'cr'
SFLT_xx'cr''lf']



Monitor & Control Module (OK/FLT)
Data Interface/Overhead Module (OK/FLT)
Battery/Clock (OK/FLT)
+5V Power Supply (OK/FLT)
+12V Power Supply (OK/FLT)
-12V Power Supply (OK/FLT)
Self Test (OK/FLT)
Mode (LOCAL or REMOTE)
Number of stored faults logged (0 to 10)
The common equipment status command causes a block of data to
be returned which indicates the status of the common equipment.

Interface
Alarms
(Backward
Alarm) Status

Command:
Response:

>add/IAS_'cr'
TXBWA1_xxx'cr'
TXBWA2_xxx'cr'
TXBWA3_xxx'cr'
TXBWA4_xxx'cr'
RXBWA1_xxx'cr'
RXBWA2_xxx'cr'
RXBWA3_xxx'cr'
RXBWA4_xxx'cr'
SFLT_xx'cr''lf']



TX Backward Alarm 1 (FLT/OK)
TX Backward Alarm 2 (FLT/OK)
TX Backward Alarm 3 (FLT/OK)
TX Backward Alarm 4 (FLT/OK)
RX Backward Alarm 1 (FLT/OK)
RX Backward Alarm 2 (FLT/OK)
RX Backward Alarm 3 (FLT/OK)
RX Backward Alarm 4 (FLT/OK)
Number of stored faults logged (0 to 10)

B.4.2 Error Performance

Raw BER

Command:
Response:

>add/RBER_xm.mE-ee'cr''lf']

Where:

x = < or > (data modifier to indicate that the error rate is
less than or greater than the returned value).
m.m = 1.0 to 9.9 (error rate mantissa).
ee = 1 to 99 (error rate exponent).

Notes:

1.

The 'x' (< or >) parameter is only returned if the
error rate has exceeded the computational
resolution of the system.

2.

'No Data' is returned if the error rate cannot be
calculated.

3.

'Sampling' is returned if not enough data is currently
available to calculate the error rate.

Corrected
BER

Command:
Response:

>add/CBER_xm.mE-ee'cr''lf']

Where:

x = < or > (data modifier to indicate that the error rate is
less than or greater than the returned value).
m.m = 1.0 to 9.9 (error rate mantissa).
ee = 1 to 99 (error rate exponent).

Notes:

1. The 'x' (< or >) parameter is only returned if the error

rate has exceeded the computational resolution of
the system.

2.

'No Data' is returned if the error rate cannot be
calculated.

3.

'Sampling' is returned if not enough data is currently
available to calculate the error rate.