Ext agc: min pwr 10.0 volts, Master reset hard/soft – Comtech EF Data SNM-1001L User Manual
Page 148
SNM-1001L Satellite Modem
Revision 1
Front Panel Operation
MN/SNM1001L.IOM
4–84
FUNCTION SELECT: UTILITY: SYSTEM: EXT AGC: MIN POWER
EXT AGC: MIN PWR
10.0 Volts
Sets the AGC voltage for a RX signal. The voltage range is 0.0 to 10.0V, in 0.5V steps. Upon
entry, the current external AGC voltage level is displayed. Press [
↑] or [↓] to increment or
decrement the AGC voltage level in 0.5V steps. Press
FUNCTION SELECT: UTILITY: SYSTEM: MASTER RESET
MASTER RESET
HARD/SOFT
Master reset function.
CAUTION
Initiating a hard reset will reset the modem and calls the default
configuration settings from ROM. Initiating a soft reset will reset the
modem hardware, but saves the current configuration settings.
Select
1. Press
[
←] or [→] to make the selection.
2. Press
3. Press
[
→] five times to move the cursor to YES.
4. Select YES and press
Note: The following parameters do not revert to default settings after a hard reset:
• Address
• Parity
• Baud Rate
• Remote Type
• Ext AGC: Min Pwr
• Ext AGC: Max Pwr
• Display Contrast