Ext agc: min pwr 10.0 volts, Master reset hard/soft – Comtech EF Data SNM-1001L User Manual

Page 148

background image

SNM-1001L Satellite Modem

Revision 1

Front Panel Operation

MN/SNM1001L.IOM

4–84

FUNCTION SELECT: UTILITY: SYSTEM: EXT AGC: MIN POWER

EXT AGC: MIN PWR

10.0 Volts



Sets the AGC voltage for a RX signal. The voltage range is 0.0 to 10.0V, in 0.5V steps. Upon
entry, the current external AGC voltage level is displayed. Press [

↑] or [↓] to increment or

decrement the AGC voltage level in 0.5V steps. Press to execute the change.

FUNCTION SELECT: UTILITY: SYSTEM: MASTER RESET

MASTER RESET

HARD/SOFT


Master reset function.

CAUTION

Initiating a hard reset will reset the modem and calls the default
configuration settings from ROM. Initiating a soft reset will reset the
modem hardware, but saves the current configuration settings.


Select once to access HARD or SOFT.

1. Press

[

←] or [→] to make the selection.

2. Press .
3. Press

[

→] five times to move the cursor to YES.

4. Select YES and press again.


Note: The following parameters do not revert to default settings after a hard reset:

• Address
• Parity
• Baud Rate
• Remote Type
• Ext AGC: Min Pwr
• Ext AGC: Max Pwr
• Display Contrast