Comtech EF Data SNM-1001L User Manual
Page 303
SNM-1001L Satellite Modem
Revision 1
Remote Control Operation MN/SNM1001L.IOM
B–29
Bulk Consol.
Status
(continued)
Parameter
Number
Parameter Name
(Command Reference)
Description
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
Transmit clock phase
(ref. 'TCP_' command).
Receive clock phase
(ref. 'RCP_' command).
Baseband loopback
ref. 'BBL_' command).
Interface loopback
(ref. 'ILB_' command).
Interface loop timing
(ref. 'ILT_' command).
TX Interface coding format
(ref. 'ICFT_' command).
RX Interface coding format
(ref. 'ICFR_' command).
Buffer clock source
(ref. 'BC_' command).
Interface RX-T1 frame structure
(ref. 'IRFS_' command).
reserved null field.
Interface RX-E1 frame structure
(ref. 'IRFS_' command).
reserved null field.
Interface Buffer Programming
(ref. 'IBP_' command).
Interface buffer size
(ref. 'IBS _' command).
Interface transmit overhead type
(ref. 'ITOT_' command).
Interface receive overhead type
(ref. 'IROT_' command).
Interface substitution pattern
(ref. 'ISP_' command).
Interface read error
(ref. 'IRE_' command).
p35 = n, where 'n' is '0' (NRM), '1' (INV), '2' (AUTO).
p36 = n, where 'n' is '0' (NRM), '1' (INV).
p37 = n, where 'n' is '0' (off) or '1' (on).
p38 = n, where 'n' is '0' (off) or '1' (on).
p39 = n, where 'n' is '0' (off) or '1' (on).
p40 = n, where 'n' is '0' (AMI), '2' (B8ZS), or '3' (HDB3).
p41 = n, where 'n' is '0' (AMI), '2' (B8ZS), or '3' (HDB3).
p42 = n, where 'n' is '0' (INT), '1' (REF), '2' (EXT), '3' (SAT),
'5' (INS).
p43 = n, where n is '0' (NONE) or '1' (G704).
p45 = n, where n is '0' (NONE) or '1' (G704).
p47 = n, where 'n' is '0' (BITS) or '1' (MS).
p48 = nnnnnn, buffer size in bits or milli seconds.
p49 = n, where 'n' is '0' (NONE), '1' (IDR), '2' (IBS), '3' (DI),
'4' (ASYNC), ‘6’ (AUPC)
p50 = n, where 'n' is '0' (NONE), '1' (IDR), '2' (IBS), '3' (DI),
'4' (ASYNC), ‘6’ (AUPC)
p51 = n, where 'n' is '0' (OFF) or '1' (ON).
p52 = n, where 'n' is '0' (OFF) or '1' (ON).