beautypg.com

Lnb current xxx ma, Lnb voltage xx volts – Comtech EF Data SNM-1001L User Manual

Page 105

background image

SNM-1001L Satellite Modem

Revision 1

Front Panel Operation

MN/SNM1001L.IOM

4–41

IMPORTANT

Conditional: This menu available only when the optional Overhead
Card is installed.


Displays the current framing pattern bit error rate or “No Data” (if carrier is not locked). Monitors
the currently selected READ_ERROR function.
Range: < mm.m E-e to > mm.m E-e.

Notes:

1.

Low limit is based on performance.

2.

High limit is based on the data/code rate.

Frame Errors

Measured when framed modes of operation are active.

2047 Errors

Measured when the RX 2047 PATTERN (under the Configuration: Interface menu)
is tuned On.

FUNCTION SELECT: MONITOR: LNB CURRENT

LNB CURRENT

XXX mA


Monitors the LNB current or “LNB POWER OFF.”
Current displayed is 0 to 500 mA in 1 mA increments.

FUNCTION SELECT: MONITOR: LNB VOLTAGE

LNB VOLTAGE

XX VOLTS


Monitors the LNB voltage or “LNB VOLTAGE OFF.”
Voltage displayed is 0 to 24 VDC, in 1volt increments.