High-Power C-Band Satellite Terminal

Redundant System Installation

Rev. 0

4–13

e.

One threaded rod at a time,
hold the washers and plate in
place on the threaded rod and
screw it into a spring nut.

Notes:

1. Be sure to position the flanges of the flat fitting plates in the grooves of

the unistruts.

2. Before tightening the nuts on the threaded rods, ensure that the end of

each rod is screwed in until it contacts the unistrut. This ensures the rods
are threaded completely through the spring nuts

f.

Tighten each nut
firmly.

g. Thread a 5/16-18 nut

about 2” onto the end
of each threaded rod.

h. Slip a 5/16” split

lockwasher, 5/16” flat
washer, and flat fitting
plate (in that order)
onto each threaded
rod.