System, B.4 system – Comtech EF Data HPCST-5000 User Manual
Page 186

Remote Control Operation
High Power C-Band Satellite Terminal
B–6
Rev. 0
B.4 System
Lock Mode
Command:
Response:
Status:
Response:
Where: xx = LK (lock) or EN (enable) (Default = Enable).
Lock mode prevents the current settings from being changed.
EIA232
Address
Select
Command:
Response:
Status:
Response:
Where:
add = Current address.
xxx = New address, 1 to 255 (Default address = 1).
EIA232
Baud Rate
Select
Command:
Response:
Status:
Response:
Where: xxxx = 300 to 19200 (In standard settings of 300, 600,
1200, 2400, 800, 9600, and 19200 kbit/s) (Default value =
9600).
EIA232
Parity
Select
Command:
Response:
Status:
Response:
Where: xx = OD (odd), EV(even), or NO (none - 8 bit) (Default
value = EV (even)).
Reference
Frequency
Adjust
Command:
Response:
Status:
Response:
Where:
nnn = DAC setting from 0 to 255.
nnn = Current DAC setting.
LNA
Calibration
Command:
Response:
Performs a current windowing calibration on the LNA.
Note: This is only done once during the initial installation.
LNA Fault
Enable
Command:
Response:
Status:
Response:
Where: xxx = ON or OFF (Default = ON, enable monitor).
External
Fault
Enable
Command:
Response:
Status:
Response:
Where: xxx = ON or OFF (Default = ON, enable monitor).
LNA Power
Enable
Command:
Response:
Status:
Response:
Where: xxx = ON or OFF (Default = ON, enable power).
Redundant
Switch
Mode
Command:
Response:
Status:
Response:
Where: xxxxx = INDEP or DEP (Default = INDEP).
Note: For use in redundant system only with RSU-503 switch.
(INDEP TX and RX switch independently on fault to backup
terminal. DEP switches both TX and RX on fault to backup
terminal.)