Single Thread System Installation

High-Power C-Band Satellite Terminal

3–14

Rev. 0

3.3.2.2 Square

Pole

For square vertical pole installation, follow the steps in Section 2.3.2.1, with the
following exceptions:

! Do not perform Step 4.
! Do not perform Step 6.e.

3.3.3 Spar

Installation

Note: Refer to Section 8, Equipment List, Figure 8-3 for assistance in the installation.

Install the RFT to a spar as follows:

1. Set the unit on its side, with the mounting holes facing up.

2. Install the 8” unistruts as follows:

a.

Position an 8” unistrut (with the open
side facing up) over one set of the
mounting holes on the RFT.

b. Using four 1/4-20 x 1” bolts, 1/4”

split lockwashers, and 1/4” flat
washers, attach an 8” unistrut to the
RFT. Tighten the bolts firmly.

c. Repeat Steps 2.a. and 2.b. for the

second 8” unistrut.