B.5 Status
Commands/Responses
Config.
Status
Command:
Response:
UCF_nnnn.nnn'cr'
DCF_nnnn.nnn'cr'
RF_xxx'cr'
DCA_nn.n'cr'
UCA_nn.n'cr'
SEL_n'cr''lf']
nnnn.nnn = 5845.000 to 6425.000 MHz.
nnnn.nnn = 3620.000 to 4200.000 MHz.
xxx = ON, WRM, or OFF.
nn.n = 0.0 to 21.0 dB (DC Fine Adj).
nn.n = 0.0 to 25.0 dB (UC Fine Adj).
n = 1, 2, 3, or NONE.
The converter configuration status command causes a block of
data to be returned by the addressed RFT-500. The block of
data reflects the current configuration status.
Fault Status
Command:
Response:
RST_xxx'cr'
UL_xxx'cr'
DL_xxx'cr'
PS5_xxx'cr'
P12_xxx'cr'
HPA_xxx'cr'
LNA_xxx'cr'
ULD_xxx'cr'
UTM_xxx'cr'
DLD_xxx'cr'
DTM_xxx'cr'
ILD_xxx'cr'
ITM_xxx'cr''lf']
Unit Experienced a Restart (OK/FLT)
Uplink Fault (OK/FLT)
Downlink Fault (OK/FLT)
+5V Power Supply (OK/FLT)
+12V Power Supply (OK/FLT)
Power Amp Fault (OK/FLT)
LNA Fault (OK/FLT)
UC LO Lock Detect (OK/FLT)
UC LO Tuning Voltage Out of Range (OK/FLT)
DC LO Lock Detect (OK/FLT)
DC LO Tuning Voltage Out of Range(OK/FLT)
IF LO Lock Detect (OK/FLT)
IF LO Tuning Voltage Out of Range(OK/FLT)
This command returns a block of data reflecting the current
and logged faults. Logged faults will be reset when receiving
this command while current faults can be read on the second
request.
Summary
Fault Status
Command:
Response:
Returns status of current faults only.
Maintenanc
e Status
Command:
Response:
UCT_nn'cr'
DCT_nn'cr'
HPT_nn'cr'
TUV_nn.n'cr'
TDV_nn.n'cr'
TIV_nn.n'cr''lf']
nn = UC temperature in deg C.
nn = DC temperature in deg C.
nn = Power Amp temp in deg C.
nn.n = Tuning voltage of UC LO.
nn.n = Tuning voltage of DC LO.
nn.n = Tuning voltage of IF LO.
This command returns a block of data from the RFT-500
reflecting the status of certain internal parameters for the
purpose of troubleshooting.
Equipment
Type Status
Command:
Response:
Where: xx = RFT-500 SW_8.00.
This command returns the equipment type polled and software
version.