1 redundant c-band sspa installation, Round pole, 5 1:1 redundant c-band sspa installation – Comtech EF Data HPCST-5000 User Manual

Page 103: 1 round pole

background image

High-Power C-Band Satellite Terminal

Redundant System Installation

Rev. 0

4–21

4.3.5

1:1 Redundant C-Band SSPA Installation

Refer to Section 8, Equipment List, Figure 8-6 for assistance in the installation of the
1:1 Redundant System. Refer to Figure 8-2 for the cabling configuration.

4.3.5.1 Round

Pole

Note: The following process is for a typical installation.

Install the 1:1 redundant assembly C-Band SSPAs to a round vertical pole as follows:

1. Set the units on a suitable work bench with the cooling fan side up.

2. Install the mounting bracket as follows:

a. Position the mounting

brackets. Align the
mounting brackets
with the mounting bolt
holes.

CAUTION

Do not block the cooling fans with the mounting bracket. Damage
to the unit may be the result

b. Install four 3/8 x 11/4” bolts 3/8” split washers, and 3/8” flat washers.

c. Tighten bolts firmly.