Cables and Connections

MN-CRS500

4–5

4.2 CRS-500 Control Connections

4.2.1 Basic CRS-500 (CSU

DSU) Unit Connection

For 1:N redundancy configurations that do not require use of the optional CRS-282xx Tx / Rx IF

Switch Units (ISUs), use a CA-0000234 Control Cable (DB-25F to DB-25M, 8’) to connect the CSU

to the DSU. This is the basic setup for all redundancy applications. Otherwise, refer to the next

section to make the Unit-to-Unit cable connections between the CRS-500 CSU, DSU, and

optional CRS-282xx ISU(s).

4.2.2 Optional CRS-500 (CSU

DSU CRS-282xx ISU) Unit

Connections

Make sure the power supply is disconnected before you connect any cables.

Serious injury or death could occur if the power supply is connected while you

connect any cables.

When a Tx IF ISU is not present, the CRS-500 will mute the offline modem(s)’ Tx IF.

When the optional Comtech EF Data CRS-282xx Tx/Rx ISUs are required, configured in either a

single IF band (i.e., 70/140 MHz or L-Band as shown in Figure 4-1) or dual IF band (i.e., 70/140

MHz and L-Band as shown in Figure 4-2), make all cable connections as instructed in this chapter

section.

First, connect and secure the CA-0000234 Control Cable (DB-25F to DB-25M, 8’) between the

CRS-500 CSU and the DSU as follows:

• DB-25M connector labeled “P2 | Switch Control” on the CSU’s CRS-530 System

Controller, to

• DB-25F connector on the rear panel of the DSU labeled “J1 | CSU/DSU CONTROL”.

Next, to interconnect the optional Tx/Rx ISUs, connect and secure the CA-0000386 Multi-drop

Control Cable (DB-9F to [4X] DB-9F, 11’) between the CRS-500 DSU and up to four CRS-282xx

Tx/Rx ISUs as follows:

• DB-9M connector labeled “P1 IF SWITCH CONTROL” on the rear panel of the CRS-500

DSU, to

• DB-9M connector labeled “TO CRS SWITCH IF CONTROL” on the rear panel of each CRS-

500 Tx/Rx ISU.

If a single IF band configuration (i.e., [1] Tx ISU and [1] Rx ISU) is deployed, be sure

to tie off or otherwise secure any of the CA-0000386 Multi-drop Control Cable’s

unused DB-9F connectors.