CRS-500 1:N Redundancy System

Revision 2

CSU Front Panel Operation

MN-CRS500

7–13

This setting does not affect the internal communications between the switch

and the modems.

CONFIG: Remote

Serial+Ether Interface

Serial Interface: RS232
RS485-2W RS485-4W

Use the ◄ ► arrow keys to select RS232, RS485-2W (2-wire), or RS485-4W (4-wire), and

then press ENTER.

If RS232 is selected, the bus address is fixed at 0000:

In RS232 mode, the bus
address is fixed at 0000

If either RS485-2W (2-wire) or RS485-4W (4-wire) is selected, you are further prompted to

enter the bus address:

Edit Switch bus address:
3000

Use the ◄ ► arrow keys to change the address value – valid addresses are 1000, 3000,

5000, and 7000 only, as explained in Chapter 9. SERIAL-BASED REMOTE PRODUCT

MANAGEMENT in this manual. Press ENTER when done.

This setting does not affect the internal communications between the switch

and the modems.

7.2.2.1.5

CONFIG: Options

Options Config: Priority
Holdoffs Alarm-Mask

These options define how the switch reacts to various faults. Use the ◄ ► arrow keys to select

Priority, Holdoffs, or Alarm-Mask, and then press ENTER.

7.2.2.1.5.1 CONFIG: Options

Priority

Priority: 2
(Press UP/DOWN, ENTER)

If one link is considered more important than all others are, this feature enables you to prioritize

that link. For example, if the switch is in Auto Mode – and it is already backing up a link that is