4 unit information commands and queries – Comtech EF Data CRS-500 User Manual

Page 176

background image

CRS-500 1:N Redundancy System

Revision 2

Serial-based Remote Product Management

MN-CRS500

9–16

9.5.4 Unit Information Commands and Queries

Parameter Type

Command

(Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of arguments

(Note that all arguments are ASCII numeric codes, that

is, ASCII codes between 48 and 57)

Response to Command

(Target to controller)

Query

(Code and

qualifier)

Response to query

(Target to controller)

Faults and Status N/A

12 bytes, alpha-

numeric

Query only.

Unit returns the current fault and status codes for the Switch

itself in the form xyABCDEFGmit, where:

x = RM1 status (0, 1, 2, 4)

0=OK

1=RM not present

2=RM comm loss

4=RM rejecting configuration string

y = * RM2 status (reserved for future use; RM2 is not

supported yet, so this will always be '*')

A = +3.3v power supply (0,1)

B = +2.5v power supply (0,1)

C = +5v power supply (0,1)

D = +12v power supply module “A” (0,1)

E = +12v power supply module “B” (0,1)

F = -12v power supply module “A” (0,1)

G = -12v power supply module “B” (0,1)

0 = OK

1 = FAULT

m = Position of TMI with mismatched data type (0..A)

i = Position of TMI with comm loss (0..A)

0 = OK

1..A = Fault

t = Temperature fault (0,1)

0 = OK

1 = FAULT

Notes:

1. It is possible to get the fault status of each CDM-625 by

querying the CDM-625 itself through the unit-addressable

remote strings (see CDM-625 manual pg D-47 for the

CDM-625 FLT query description).

2. The CRS-500 ties up the telnet connection on each CDM-

625, so it is necessary to execute these queries through

the CRS-500 remote control interface (serial or telnet):

<0000/FLT? = Fault status of CRS-500 controller

<0100/FLT? = Fault status of TM1

<0200/FLT? = Fault status of TM2

<1000/FLT? = Fault status of TM10

<1100/FLT? = Fault status of RM1

N/A

FLT?

FLT=

xABCDEFGmit

(see description of

arguments)