CSU Front Panel Operation
MN-CRS500
7–19
7.2.2.3.2.1 STATUS: Events
View
001: 26/01/00 10:37:32
FT-06 RX ALARM (UP/DN)
When a fault (FT) condition occurs, it is date- and time-stamped and put into the log (note that
the date is shown in DAY/MONTH/YEAR format, in accordance with international convention).
Similarly, when the fault condition clears (OK), this is also recorded, as shown in the example
that follows:
024: 26/01/04 10:37:35
OK-06 RX ALARM (UP/DN)
Use the ◄ ► arrow keys to scroll backwards or forwards through the entries in the event log.
The event log can store up to 255 events. Next to the FT/OK indicator is a number/code for the
faulted unit: the TM slot number (01 through 10), RM (for Redundant Modem) or SW (for the
switch). Press ENTER or CLEAR to return to the previous menu.
7.2.2.3.2.2 STATUS: Events
Clear-all
Stored Events Cleared.
press ENTER
If Clear-all is selected, the log is cleared and the message “
Stored Events Cleared. Press
ENTER
” is displayed. Press ENTER or CLEAR to return to the previous menu.
7.2.2.3.3
STATUS: Temp (Temperature)
Temperature:
+37 degrees Celsius
This is a ‘status only’ display. Press ENTER or CLEAR to return to the previous menu.
7.2.2.3.4
STATUS: Types (Card Types)
Card Types: slot 01
none
This screen displays the available Traffic Modem Interfaces (TMIs) and Redundant Modem
Interfaces (RMIs), as installed on a per-slot basis.
7.2.2.3.5
STATUS: Comms (Communications State)
Comms OK with:
1 2 3 - 5 - 7 8 – 10 11
This screen displays that the switch has good monitoring I/O communications with the indicated
modems.