CRS-500 1:N Redundancy System

Revision 2

CSU Front Panel Operation

MN-CRS500

7–19

7.2.2.3.2.1 STATUS: Events

View

001: 26/01/00 10:37:32
FT-06 RX ALARM (UP/DN)

When a fault (FT) condition occurs, it is date- and time-stamped and put into the log (note that

the date is shown in DAY/MONTH/YEAR format, in accordance with international convention).

Similarly, when the fault condition clears (OK), this is also recorded, as shown in the example

that follows:

024: 26/01/04 10:37:35
OK-06 RX ALARM (UP/DN)

Use the ◄ ► arrow keys to scroll backwards or forwards through the entries in the event log.

The event log can store up to 255 events. Next to the FT/OK indicator is a number/code for the

faulted unit: the TM slot number (01 through 10), RM (for Redundant Modem) or SW (for the

switch). Press ENTER or CLEAR to return to the previous menu.

7.2.2.3.2.2 STATUS: Events

Clear-all

Stored Events Cleared.
press ENTER

If Clear-all is selected, the log is cleared and the message “

Stored Events Cleared. Press

ENTER

” is displayed. Press ENTER or CLEAR to return to the previous menu.

7.2.2.3.3

STATUS: Temp (Temperature)

Temperature:
+37 degrees Celsius

This is a ‘status only’ display. Press ENTER or CLEAR to return to the previous menu.

7.2.2.3.4

STATUS: Types (Card Types)

Card Types: slot 01
none

This screen displays the available Traffic Modem Interfaces (TMIs) and Redundant Modem

Interfaces (RMIs), as installed on a per-slot basis.

7.2.2.3.5

STATUS: Comms (Communications State)

Comms OK with:
1 2 3 - 5 - 7 8 – 10 11

This screen displays that the switch has good monitoring I/O communications with the indicated

modems.