Comtech EF Data CRS-500 User Manual
Page 175

CRS-500 1:N Redundancy System
Revision 2
Serial-based Remote Product Management
MN-CRS500
9–15
Parameter Type
Command
(Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of arguments
(Note that all arguments are ASCII numeric codes, that
is, ASCII codes between 48 and 57)
Response to Command
(Target to controller)
Query
(Code and
qualifier)
Response to query
(Target to controller)
Local/ Remote
Status
LRS=
1 byte, value of 0,
1, or 2
Command or Query.
Sets or returns the local/remote status of the Switch in the
form x, where:
0 = Front Panel
1 = Ethernet
2 = Serial and Ethernet
LRS=
LRS?
LRS?
LRS=x
(see description of
arguments)
MAC Address
N/A
12 bytes, alpha-
numerical
Query only.
Returns the unique MAC Address for the Switch.
Example: MAC=0006B00001CA
N/A
MAC?
MAC=aabbccddeeff
(see description of
arguments)
SNMP Read
Community
SRC=
Up to16 bytes,
characters, no
spaces
Command or Query.
Sets or returns the SNMP Read Community string.
Example: SRC=public
Notes:
1. Empty string is not allowed
2. Reboot is required in order for changes to the Read
Community string to take effect.
SRC =
SRC!
SRC?
SRC=x…x
(see description of
arguments)
SNMP
Write
Community
SWC=
Up to 16 bytes,
characters, no
spaces
Command or Query.
Sets or returns the SNMP Write Community string.
Example: SWC=public
Notes:
1. Empty string is not allowed
2. Reboot is required in order for changes to the Write
Community string to take effect.
SWC =
SWC!
SWC?
SWC=x…x
(see description of
arguments)