beautypg.com

Comtech EF Data CRS-500 User Manual

Page 175

background image

CRS-500 1:N Redundancy System

Revision 2

Serial-based Remote Product Management

MN-CRS500

9–15

Parameter Type

Command

(Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of arguments

(Note that all arguments are ASCII numeric codes, that

is, ASCII codes between 48 and 57)

Response to Command

(Target to controller)

Query

(Code and

qualifier)

Response to query

(Target to controller)

Local/ Remote

Status

LRS=

1 byte, value of 0,

1, or 2

Command or Query.

Sets or returns the local/remote status of the Switch in the

form x, where:

0 = Front Panel

1 = Ethernet

2 = Serial and Ethernet

LRS=

LRS?

LRS?

LRS=x

(see description of

arguments)

MAC Address

N/A

12 bytes, alpha-

numerical

Query only.

Returns the unique MAC Address for the Switch.

Example: MAC=0006B00001CA

N/A

MAC?

MAC=aabbccddeeff

(see description of

arguments)

SNMP Read

Community

SRC=

Up to16 bytes,

characters, no

spaces

Command or Query.

Sets or returns the SNMP Read Community string.

Example: SRC=public

Notes:

1. Empty string is not allowed

2. Reboot is required in order for changes to the Read

Community string to take effect.

SRC =

SRC!

SRC?

SRC=x…x

(see description of

arguments)

SNMP

Write

Community

SWC=

Up to 16 bytes,

characters, no

spaces

Command or Query.

Sets or returns the SNMP Write Community string.

Example: SWC=public

Notes:

1. Empty string is not allowed

2. Reboot is required in order for changes to the Write

Community string to take effect.

SWC =

SWC!

SWC?

SWC=x…x

(see description of

arguments)