CRS-500 1:N Redundancy System

Revision 2

Serial-based Remote Product Management

MN-CRS500

9–13

Parameter Type

Command

(Code and

qualifier)

Arguments for

Command or

Response to

Query

Description of arguments

(Note that all arguments are ASCII numeric codes, that

is, ASCII codes between 48 and 57)

Response to Command

(Target to controller)

Query

(Code and

qualifier)

Response to query

(Target to controller)

TMI/RMI types

N/A

11 Bytes

Query only.

Returns theTMI type detected in each slot position in the form

xxxxxxxxxxy, where:

0 = none present

1 = CRS-320 Rev A

2 = CRS-330

3 = CRS-340 Rev A

4 = CRS-340 Rev B

6 = CRS-320 Rev C

7 = Undefined

8 = CRS-341

9 = CRS-316

A = CRS-336

B = Undefined

C = CRS-315 (TMI)

D = CRS-325 (TMI)

E = CRS-335 (TMI)

F = CRS-345

G = CRS-365 Quad E1 for CDM-Qx

H = CRS Quad E1 D-sub for CDM-625

K = CRS-515

L = CRS-520

M = CRS-516

N = CRS-517

y indicates the RMI type detected in slot II, where:

0 = none present

7 = CRS-310

D = CRS-307

E = CRS-306

F = CRS-305

I = CRS-505

J = CRS-510

Example: XMI=21000000007

N/A

XMI?

XMI=xxxxxxxxxxy

(see description of

arguments)