CRS-500 1:N Redundancy System

Revision 2

CSU Front Panel Operation

MN-CRS500

7–18

If the second power supply module is not needed, you can mask this alarm.

Example 3:

Switch Alarm: RM Problem
RM I/O Timeout

There is a fault. Communication has been lost to the Redundant Modem. The front panel LED

“Unit Status” will be red.

Suggestions:

Check Cable Connections – refer to Chapter 4. CABLES

AND

CONNECTIONS.

Check Modem Configurations – refer to Chapter 6. CONFIGURING MODEMS

FOR

1:N REDUNDANCY.

Example 4:

Switch Alarm: RM Problem
MGC refused, code:12 TFT

There is a fault. COMMs are good to the Redundant Modem, but the configuration of the

bridged Traffic Modem cannot be configured into the Redundant Modem. The front panel LED

“Unit Status” will be red.

Suggestion: Ensure that the most capable modem – with regard to FAST options, installed

options, etc. (e.g. Turbo card, firmware version, and hardware revision) – is used as the

Redundant Modem. The code indicates the parameter within the MGC configuration string that

is causing rejection by the Redundant Modem. The three-letter instruction code is indicated also

to assist you in decoding the problem parameters.\

7.2.2.3.2

STATUS: Events (Stored Events)

Stored Events: View
Clear-all

Use the ◄ ► arrow keys to select View or Clear-All, and then press ENTER.

If Clear-All is selected, the event log is cleared and you are taken directly back to the previous

menu. However, if there are faults present on the unit at this time, new log entries will be

generated for those faults.