Comtech EF Data CRS-500 User Manual
Page 110

CRS-500 1:N Redundancy System
Revision 2
Updating Firmware
MN-CRS500
5–10
During this time you may click [click
to cancel] to abort the process.
Should you allow reboot to proceed,
the following messages appear during
the reboot process:
6. If needed, update the alternate firmware image.
Should you desire to update the originally-selected image slot – i.e., the slot that was in use
at the time the file upgrade was applied to the slot not in use – follow these steps:
A. As per Step 5, open the Utility | Boot Slot page and use the ‘Boot From:’ drop-down list
to select the newly-upgraded image as the designated image from which to boot, and
then click [Update].
B. Reboot the system as per Step 6. Once the reboot is complete, click [click to continue]
to return to the Utility | Boot Slot page.
With the newly-upgraded image now selected and active, repeat Steps 1 through 6 to
automatically upload the firmware file upgrade to the alternate image slot.
The Firmware Update process is now complete.