CRS-500 1:N Redundancy System
Revision 2
CSU Front Panel Operation
MN-CRS500
7–12
7.2.2.1.3.3 CONFIG: IP
Mgt-IP (Management IP Address)
Management IP Address:
000.000.000.000/00
View or edit the Management IP Address for Monitor and Control (M&C) communication here.
To edit the M&C Management IP Address: On the bottom line, use the ◄ ► arrow keys to
select the digit to edit, and then use the ▲▼ arrow keys to edit that digit. Press ENTER when
done.
7.2.2.1.3.4 CONFIG: IP
Gateway
Gateway IP Address:
000.000.000.000/00
View or edit the Gateway IP Address for the Ethernet M&C port for this unit here.
To edit the Gateway IP Address: On the bottom line, use the ◄ ► arrow keys to select the digit
to edit, and then use the ▲▼ arrow keys to edit that digit. Press ENTER when done.
7.2.2.1.4
CONFIG: Remote
Remote Config: Local
Ethernet Serial+Ether
Use the ◄ ► arrow keys to select Local, Ethernet, or Serial+Ether, and then press ENTER.
7.2.2.1.4.1 CONFIG: Remote
Local
If Local is selected, then reconfiguration via Ethernet or Serial+Ether(net) is not
allowed. Remote monitoring is still possible.
7.2.2.1.4.2 CONFIG: Remote
Serial+Ether
Serial Config:
Baudrate Interface
Use the ◄ ► arrow keys to select Baudrate or Interface, and then press ENTER.
CONFIG: Remote
Serial+Ether Baudrate
Serial Baudrate: 19200
Select the baud rate of the remote control bus connected locally to the M&C computer. Use
the ◄ ► arrow keys to change the rate – baud rates of 300, 1200, 2400, 4800, 9600 and
19200 are possible – and then press ENTER.